Baumüller BUM60-1224-54-B-001-VC-A0-0093-0013-G003-000

Key Features

  • Precision Actuation Control: BUM60 drive + 3522-1004 driver delivers ±0.1% position accuracy for servo valves to maintain stable turbine/genset output.
  • VC-A0 Control Firmware: BUM60’s VC-A0-0093 firmware supports position/velocity/force control modes for multi-axis coordination in industrial systems.
  • G003 Safety Compliance: BUM60 includes E-Stop, safe torque off (STO), and overcurrent protection for IEC 61508 SIL 2 applications.
  • Fast Response Time: ≤10 ms signal-to-output latency enables real-time adjustment of servo valve position during load changes.
  • Modbus RTU Integration: Both units support RS-485 Modbus RTU for remote monitoring/configuration via PLC/DCS/SCADA.
  • Dual Power Compatibility: BUM60 operates on 12/24 Vdc; 3522-1004 uses 24 Vdc for flexible installation in mobile/industrial setups.
  • Redundant I/O Support: Optional dual analog inputs for critical applications requiring signal validation and fail-safe operation.
  • Thermal Management: Active cooling (BUM60) and passive heat dissipation (3522-1004) ensure reliable operation at 70°C max temp.
Category:
Description

Technical Specifications

Parameter Baumüller BUM60-1224-54-B-001 (VC-A0-0093-G003) Woodward 3522-1004 Servo Valve Driver
Product Series BUM60 Compact Servo Drives Woodward Electro-Hydraulic Servo Valve Drivers
Power Supply 12/24 Vdc (9–36 Vdc range); max power 1.2 kW; reverse polarity protected 24 Vdc (18–32 Vdc); max current 2 A; power consumption 48 W
Output Current Continuous: 18 A; peak: 54 A (3 s); short-circuit protected 4–20 mA / 0–10 Vdc (max 500 mA) for servo valve coils
Control Interface VC-A0-0093 firmware; position/velocity/force control; 2×encoder inputs (TTL/HTL) Analog input (0–10 Vdc/4–20 mA); PWM input (0–100% duty cycle); Modbus RTU
Safety Features G003 safety rating; overcurrent/overvoltage/overtemperature protection; emergency stop (E-Stop) input Overcurrent trip; short-circuit protection; signal loss alarm; thermal shutdown
Communication RS-485 (Modbus RTU); CANopen optional; supports parameter upload/download RS-485 (Modbus RTU); USB for local configuration via Woodward Control Assistant
Environmental Ratings Operating temp: -40°C to 70°C; IP20 (chassis)/IP54 (front panel); humidity 0–95% non-condensing Operating temp: -40°C to 60°C; IP20; pollution degree 3; Class 1 Division 2 compliant
Physical Form Factor Panel-mount; 175 mm × 100 mm × 50 mm; weight 0.8 kg DIN-rail/panel-mount; 100 mm × 80 mm × 40 mm; weight 0.3 kg
Certifications CE, UL, RoHS; IEC 61800-5-1 compliant CE, UL; IEC 61508 SIL 2 compliant for safety-critical applications

Functional Capabilities

  • Closed-Loop Position Control: Uses encoder feedback (BUM60) and servo valve position sensors (3522-1004) to maintain setpoint accuracy across load variations.
  • Servo Valve Driving: Converts digital control signals to precise current outputs for proportional/servo valves in steam/gas turbine fuel systems.
  • Safety Interlocks: Triggers E-Stop and STO on overcurrent/overtemperature to prevent equipment damage and personnel injury.
  • Parameter Upload/Download: Stores 10+ configuration sets for quick replacement of failed modules; exports logs via USB/SD card.
  • Real-Time Monitoring: Measures valve position, coil current, and supply voltage; logs faults (overcurrent, signal loss) for troubleshooting.
  • Remote Setpoint Adjustment: Accepts 0–10 Vdc/4–20 mA analog inputs from PLC/DCS for dynamic control of valve position.
  • Fail-Safe Operation: Returns valve to a safe position (closed/open) upon power loss or communication failure.

Application Scenarios

  • Steam/Gas Turbines: Controls inlet steam/gas valves for speed/load regulation in power generation plants and petrochemical refineries.
  • Diesel Genset Actuation: Drives fuel control valves and throttle actuators to maintain stable frequency/voltage in standby/prime power systems.
  • Industrial Hydraulics: Operates proportional valves in metal forming, injection molding, and material handling equipment requiring precise force/position control.
  • Marine Propulsion: Controls shipboard turbine fuel valves and thrust reversers for dynamic speed and direction changes.
  • Hazardous Locations: Class 1 Division 2 compliant for oil/gas platforms and chemical plants needing explosion-proof actuation control.
  • Cogeneration (CHP) Systems: Balances steam/fuel flow to optimize heat/power output in combined heat and power applications.

Configuration & Maintenance

  • Local Configuration: BUM60 uses front-panel buttons + LCD; 3522-1004 uses USB and Woodward Control Assistant for parameter setup.
  • PC-Based Programming: BUM60 configures via Baumüller’s ProDrive software; 3522-1004 uses Control Assistant to set current limits, PWM frequency, and safety thresholds.
  • Encoder Calibration: BUM60 auto-calibrates to TTL/HTL encoders (100–10,000 PPR) for accurate position feedback; triggers alarms on signal loss.
  • Firmware Updates: Both units support in-field upgrades via serial/USB to add features and maintain compliance with industry standards.
  • Diagnostic Tools: Front-panel LEDs indicate power, communication, and fault status; logs 100+ time-stamped events for fast troubleshooting.
  • Module Replacement: Drop-in compatibility with legacy BUM60/3522 series modules minimizes retrofit costs and downtime.
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Baumüller BUM60-1224-54-B-001-VC-A0-0093-0013-G003-000”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.