TRIC0NEX 3481

Technical Specifications:

  • It is designed for high availability and fault tolerance, ensuring continuous operation even in the event of hardware failures.
  • The system supports safety integrity levels up to SIL 3 according to IEC 61508, making it suitable for critical safety applications.
  • It operates with a triple modular redundant (TMR) architecture where three independent systems process data simultaneously and compare results to ensure accuracy and reliability.

TRICONEX 3009 – Main Processor Module

技术规格:
  • Triconex 3009 是一款三重冗余控制器,支持符合 IEC 61508 的安全完整性等级 3 (SIL 3),确保高可靠性和容错能力。
  • 它可以在恶劣的环境条件下运行,并具有适合工业环境的特定温度范围。
  • 支持各种输入/输出模块,以便与传感器、执行器以及过程控制和安全功能所需的其他现场设备进行接口。
  • 配备通信接口,可与分布式控制系统 (DCS)、监控和数据采集 (SCADA) 系统以及其他工厂范围的网络无缝集成。

Triconex 3201 Communication Module

Technical Specifications:
  • System Architecture: The 3201 model is part of a triply redundant architecture, offering fault tolerance and high availability. This triple modular redundancy (TMR) ensures continuous operation even in the event of hardware failures.
  • Processor Capabilities: Equipped with powerful processors capable of executing complex control logic and diagnostics simultaneously across three channels to ensure reliable operation.
  • Memory: Includes sufficient memory for storing application programs, historical data, and system parameters, supporting extensive configuration and logging capabilities.
  • Communication Interfaces: Supports various communication protocols including Modbus, OPC, and proprietary interfaces, enabling seamless integration with distributed control systems (DCS) and other plant networks.

Triconex 4355X

Technical Specifications
  • Architecture: Triple Modular Redundancy (TMR) for fault tolerance.
  • Processor: High-performance CPU with sufficient memory for complex control tasks.
  • Communication Protocols:
    • Modbus (RTU/TCP) for integration with PLCs and SCADA systems.
    • Profibus DP for real-time control of sensors and actuators in factory automation.
    • Ethernet for high-speed data exchange and remote monitoring.
  • Input/Output (I/O):
    • Digital Inputs/Outputs: 16 isolated digital inputs and 8 relay outputs (potential-free contacts).
    • Analog Support: Optional integration with analog modules for temperature, pressure, and flow monitoring.

TRICONEX 8310 High-Density Power Module

Technical Specifications

  • Processor: Equipped with triple modular redundancy (TMR) architecture for enhanced reliability and fault tolerance
  • Communication Interfaces: Supports multiple communication protocols such as Modbus, Ethernet, and proprietary Triconex protocols for integration with different systems
  • Memory: Sufficient onboard memory for storing application programs and data, ensuring reliable operation without data loss
  • Power Supply: Operates on standard industrial power supplies, typically 24V DC or 110/230V AC depending on configuration
  • Operating Temperature: Designed for stable operation within industrial environments, generally from -20°C to +60°C

TRICONEX 9563-810 Digital Input Termination Panel

Technical Specifications:

  • Type: Typically serves as an interface or communication module within the Tricon system.
  • Communication Protocols: Supports industry-standard protocols to ensure compatibility with various control systems and devices.
  • Power Supply: Operates within specified voltage ranges suitable for industrial environments.
  • Environmental Endurance: Designed to withstand harsh conditions including wide temperature ranges, humidity, and exposure to dust.
  • Certifications: Certified for use in Safety Instrumented Systems (SIS) up to Safety Integrity Level 3 (SIL 3), ensuring compliance with stringent safety standards.

TRICONEX AI2351 7400210-010

  • Number of Channels: 8
  • Input Range: 4 mA to 20 mA
  • Accuracy: ±0.25%
  • Response Time: Less than 250 ms
  • Power Consumption: 24 VDC, 2.5 A
  • Operating Temperature: - 40°C to +70°C
  • Humidity: 0% to 95% non - condensing
  • Supported Input Signal Types: Voltage (±10V, 0 - 10V) and current (4 - 20mA) (additional information from another source)

Triconex AO3481 Analog Output Module

Technical Specifications:
  • Channel Count: Typically offers multiple channels (the exact number should be confirmed from the official documentation) for connecting various analog output devices.
  • Signal Range: Supports standard analog signal ranges, including 4-20mA and possibly voltage ranges like 0-10V, ensuring compatibility with a wide array of field instruments.
  • Resolution: High-resolution outputs that ensure precise control of connected devices, contributing to accurate process management.
  • Redundancy: Designed with redundancy options to enhance system reliability and availability, critical for safety applications.

TRICONEX CM3201 – Communication Module for Safety-Critical Systems

Technical Specifications:

  • Type: Communication Module
  • System Compatibility: Designed to work within the Tricon system architecture, supporting seamless integration with other Tricon components.
  • Communication Protocols: Supports various industry-standard communication protocols, facilitating connectivity with Distributed Control Systems (DCS), Supervisory Control and Data Acquisition (SCADA) systems, and other plant networks.