ICS Triplex T8850 Triple Modular Redundant (TMR) Digital Input/Output Module

Technical Specifications
  • Channels: 40 digital input/output channels (configurable for either input or output).
  • Voltage Range:
    • Operating voltage: 24 V DC (standard); supports up to 60 V DC via external power distribution units.
    • Field terminal wire size: 12 AWG to 28 AWG.
  • Current Rating:
    • Maximum current per channel: 2 A.
    • Power dissipation: 0.5 W per power group.
  • Isolation:
    • Channel-to-channel isolation: 50 V reinforced (continuous), tested at 1411 V DC for 60 seconds.
    • Power group-to-power group isolation: 250 V basic (fault), tested at 2436 V DC for 60 seconds.

ICS Triplex T9100 Trusted Triple Modular Redundant (TMR) Controller

Technical Specifications
  • Processor Architecture: Triple-redundant design with three independent processor modules.
  • Input Voltage: 24 V DC.
  • Operating Temperature: -40 °C to +70 °C.
  • Storage Temperature: -25 °C to +70 °C.
  • Humidity: 10% to 95% non-condensing.
  • Communication Protocols: Supports Modbus TCP/IP, EtherNet/IP, Profinet, and other industrial protocols.
  • Dimensions: 100 mm × 120 mm × 30 mm.
  • Weight: Approximately 1.5 kg (depending on configuration).
  • Memory: Variable binding memory increased from 64K to 128K for enhanced data handling.
  • Redundancy: Redundant power supplies, communication interfaces, and I/O modules.

ICS Triplex T9110 Advanced Processor Module

Technical Specifications
  • Processor Architecture: Triple modular redundant (TMR) with three independent 32-bit processors executing in parallel.
  • Memory: Standard main memory supporting complex logic programs.
  • Scan Cycle: High-speed scanning with typical values as low as milliseconds.
  • Communication Interfaces: Supports TriBus (TMR bus), ControlNet, EtherNet/IP, Profinet, and Modbus protocols.
  • Safety Certifications: IEC 61508 SIL 3, TÜV-certified for safety-critical applications.
  • Operating Temperature: 0 °C to 60 °C (standard industrial range).
  • Power Supply: 20 V DC to 32 V DC, with redundant power options available.
  • Dimensions: Designed for insertion into the leftmost slot of the main system rack.
  • Weight: Approximately 2.94 kg (shipping weight: 4 kg).

ICS Triplex T9402 Controller Module

Technical Specifications
  • Redundancy Architecture: Triple modular redundant (TMR) design with three independent CPUs, power supplies, and I/O modules for fault tolerance.
  • Processor: 64-bit CPU with a clock speed of ≥1 GHz, enabling high-speed data processing and complex control algorithm execution.
  • Memory: RAM ≥2 GB, Flash ≥512 MB, supporting large-scale program storage and rapid data access.
  • Input/Output Channels:
    • Digital Input: Up to 32 channels (expandable to 128 channels), supporting 0-32 V DC signals.
    • Digital Output: Supports relay outputs (max load 2 A/30 V DC).
  • Communication Interfaces: Ethernet (10/100 Mbps), RS-485, Profibus-DP, Modbus TCP/RTU for seamless integration with other systems.
  • Switching Time: ≤1 millisecond (from fault detection to main-backup switchover).
  • Safety Certifications: TÜV SIL 3, IEC 61508, and IEC 61511 compliant, ensuring compliance with international safety standards.

ICS Triplex T9432 High-Precision Analog Input Module

Technical Specifications
  • Input Channels: 16 channels (configurable for 32-channel redundancy via TMR design).
  • Input Types: Supports multiple analog signals, including 0-10V, 4-20mA, ±10V, ±5V, ±2.5V, ±1V, 0-20mA.
  • Accuracy: ±0.1% FSR (Full Scale Range, typical).
  • Sampling Rate: Configurable up to 100 samples per second per channel (typical).
  • Resolution: 16-bit.
  • Isolation Voltage: 500Vdc (between channels and between channels and system).
  • Common-Mode Rejection Ratio (CMRR): >120dB (typical).
  • Operating Temperature: -40°C to +70°C.
  • Storage Temperature: -40°C to +85°C.
  • Humidity: 5% to 95% RH (non-condensing).

ICS Triplex T9802 Digital Input Module

Technical Specifications
  • Input Channels: 16 dual-isolated digital inputs (TA16 configuration).
  • Voltage Rating: 24 V DC (standard), with compatibility for higher voltages via external power distribution units.
  • Isolation:
    • Channel-to-channel isolation: 50 V reinforced (continuous), tested at 1411 V DC for 60 seconds.
    • Power group-to-power group isolation: 250 V basic (fault), tested at 2436 V DC for 60 seconds.
  • Response Time: Less than 2 milliseconds for rapid signal processing.
  • Environmental Resistance:
    • Operating temperature: -40 °C to +70 °C.
    • Storage temperature: -25 °C to +70 °C.
    • Humidity: 10% to 95% non-condensing.

ICS Triplex T9852 High-Performance Industrial Automation Module

Technical Specifications
  • Redundancy Architecture: Triple modular redundancy (TMR) with 3-2-0 fault-tolerant operation.
  • Input/Output Channels:
    • Digital Input: Supports up to 16 channels (e.g., 24V DC, 8-channel or 16-channel configurations).
    • Digital Output: 8-channel or 16-channel options available, with each channel supporting up to 1A load.
    • Analog Input/Output: Some variants support 8-channel or 16-channel analog inputs/outputs with 16-bit resolution.
  • Processor: High-performance processor with speeds ranging from 15-30Hz, enabling real-time control and monitoring.