GE SFLA36AT0250

Product Overview

The GE SFLA36AT0250 is a 3-pole molded case circuit breaker (MCCB) from the Spectra RMS™ series, engineered for industrial and commercial power distribution systems requiring precise, reliable overcurrent protection. It features a digital solid-state RMS sensing trip unit with LSI (Long-Time, Short-Time, Instantaneous) protection functions, adjustable settings, and field-installable rating plugs for flexible ampacity configuration (70–250A). The bolt-on mount design ensures secure panelboard installation, while current-limiting technology minimizes fault energy let-through to protect downstream equipment.
Category:
Description

Technical Specifications

Parameter Details
Model Number SFLA36AT0250
Manufacturer General Electric (GE)
Product Series Spectra RMS™
Frame Size SF250 (70–250A adjustable range)
Poles/Phase 3 poles, 3-phase
Rated Current (Iₙ) 250A (adjustable via rating plug: 70–250A)
Rated Voltage (Uₙ) 600VAC (max)
Interrupt Rating (Iₙᵗ) 100 kAIC @ 240VAC; 65 kAIC @ 480VAC; 25 kAIC @ 600VAC
Trip Unit Type Digital solid-state RMS sensing
Protection Functions LSI: Long-Time (overload), Short-Time (fault), Instantaneous (high-current)
Mounting Type Bolt-on (panelboard/switchgear compatible)
Wire Range 8 AWG to 350 kcmil (aluminum/copper)
Frequency 50/60 Hz
Operating Temperature -25°C to 60°C
Storage Temperature -40°C to 85°C
Dimensions (H×W×D) 10.12 in × 4.12 in × 3.81 in (257 mm × 105 mm × 97 mm)
Weight 10 lbs (4.54 kg)
Certifications UL Listed, CSA Certified, CE Marked, HACR Rated, NOM compliant
Enclosure Ratings Compatible with NEMA 1, 3R, 4, 4X, 12
Trip Unit Features Adjustable instantaneous, tracking short-time, digital RMS sampling
Connection Type Bolt-on terminals (600VAC/250A)

Function Features

  • Digital RMS Sensing: Measures true RMS current for accurate protection against sinusoidal and non-sinusoidal loads (VFDs, SMPS), eliminating false trips from harmonic distortion.
  • LSI Protection: Long-Time (inverse-time overload), Short-Time (adjustable time/current for coordination), and Instantaneous (fixed/magnetic for high faults) functions cover all overcurrent scenarios.
  • Adjustable Settings: Field-installable rating plugs set ampacity (70–250A); front-panel dials tune short-time pickup (0.5–10×Iₙ) and time delay (0.05–10s); instantaneous pickup (3–15×Iₙ) tracks short-time settings for coordination.
  • Current-Limiting Design: Reduces fault energy let-through, minimizing thermal/mechanical stress on cables, transformers, and motors.
  • Bolt-On Mount: Secure panelboard/switchgear installation with standard hardware; compatible with NEMA enclosures.
  • Wide Interrupt Ratings: 100/65/25 kAIC across 240/480/600VAC ensures protection at all system voltages.
  • Global Certifications: UL, CSA, CE, HACR, NOM compliance for use in North American and international systems.
  • Harmonic Tolerance: Digital sampling handles up to 30% THD without performance degradation.
  • Field Serviceability: Rating plugs and lugs are field-replaceable; no special tools needed for configuration.
  • Visual Status Indicators: Pivot/toggle handle shows ON/TRIPPED/OFF states for quick diagnostics.

Application Scenarios

  • Industrial Panelboards: Protects branch circuits in manufacturing plants, handling mixed loads (motors, heaters, VFDs) with adjustable LSI settings.
  • Commercial Building Distribution: Powers HVAC, lighting, and elevator systems in high-rise buildings; meets NEC/CEC coordination requirements.
  • Motor Control Centers (MCCs): Guards 3-phase motors against overload, locked rotor, and short-circuit faults; coordinates with contactors and overload relays.
  • Switchgear Assemblies: Used in medium-voltage switchgear for secondary-side protection; current-limiting reduces arc-flash hazards.
  • Data Centers: Protects UPS systems, server racks, and cooling infrastructure from harmonic-rich, high-current faults.
  • Petrochemical Facilities: Installed in Zone 2/Class I, Div 2 non-hazardous areas to protect process pumps and compressors.
  • Water/Wastewater Treatment: Guards pump stations and aeration systems against overloads from variable-speed drives.
  • Renewable Energy Inverters: Protects grid-tie inverters and DC/AC distribution in solar/wind farms; handles non-sinusoidal inverter currents.

Compatibility and Integration

  • Rating Plugs: Uses GE Spectra RMS™ front-mounted rating plugs (e.g., 250A, 200A) for ampacity adjustment; no tools required for replacement.
  • Lug Compatibility: Accepts 8 AWG to 350 kcmil copper/aluminum lugs (standard compression or bolt-on); rated for 600VAC/250A.
  • Controller Integration: Works with GE Multilin relays, Allen-Bradley PLCs, and Siemens S7 systems via auxiliary contacts (optional); supports remote monitoring via Modbus (with add-on communication module).
  • Panelboard Compatibility: Fits standard NEMA 1/3R/4/4X/12 panelboards; bolt-on terminals align with industry mounting patterns.
  • Coordination with Fuses: Coordinates with Class J/K/L fuses for selective tripping; short-time delay prevents nuisance tripping during inrush currents.
  • Replacement for Legacy Breakers: Drop-in replacement for older GE SF250-frame MCCBs; no panel modifications needed.
  • Maintenance Tools: Compatible with GE Trip Unit Test Kits for verifying LSI settings without system shutdown.
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “GE SFLA36AT0250”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.