ICS Triplex TC-505-02-4M5 4.5-Meter Trusted I/O SmartSlot Cable

Technical Specifications

  1. Electrical & Signal Specifications
    • Cable Type: 34-core shielded multi-conductor (24 AWG stranded copper)
    • Voltage Rating: 300 V AC/DC (continuous operation)
    • Current Rating: 2 A per conductor (max load)
    • Insulation Resistance: ≥100 MΩ (at 500 V DC)
    • Shielding: Foil + braid dual shielding (shielding effectiveness ≥90 dB at 100 kHz–1 GHz)
    • Impedance: 120 ohms (signal pairs)
    • Capacitance: ≤25 pF per meter (conductor-to-conductor)
    • Attenuation: ≤1 dB per meter at 1 MHz
    • Signal Isolation: 2500 Vrms (module-to-FTA, 1 minute)
Category:
Description
  1. Mechanical Specifications
    • Length: 4.5 meters (14.76 feet) ± 0.1 meters (factory-calibrated)
    • Connectors: 96-way Type ‘C’ male (chassis end, IEC 60807-3) + FTA-compatible flying leads (field end)
    • Jacket Material: Oil-resistant PVC (UL 94 V-0 flame-retardant)
    • Strain Relief: Molded thermoplastic strain relief at both ends
    • Cable Diameter: 8 mm (0.31 inches)
    • Minimum Bend Radius: 35 mm (dynamic); 20 mm (static)
    • Weight: 0.75 kg (1.65 lbs)
    • Connector Protection: Dust cap for Type ‘C’ connector (factory-installed)
  2. Environmental Specifications
    • Operating Temperature: -40°C to +70°C (-40°F to +158°F)
    • Storage Temperature: -55°C to +85°C (-67°F to +185°F)
    • Relative Humidity: 5%–95% (non-condensing)
    • Vibration Resistance: IEC 60068-2-6 (2 g, 10–150 Hz)
    • Shock Resistance: IEC 60068-2-27 (15 g, 11 ms duration)
    • Oil Resistance: Compliant with ISO 7628 (resistant to mineral oil, hydraulic fluid, and industrial solvents)
    • Flame Retardancy: UL 94 V-0 (self-extinguishing within 10 seconds)
  3. Compliance & Compatibility
    • Safety Certification: IEC 61508 SIL 3 compliant (system-level)
    • Regulatory Compliance: CE marked, RoHS compliant, REACH compliant
    • System Compatibility: Trusted T8100 series I/O modules (T8400 digital output, T8450 analog output), T8850C FTA, T8100 chassis
    • Quality Standard: Manufactured to ICS Triplex ISO 9001 quality management system; 100% factory tested for electrical and mechanical performance

Functional Features

  1. 4.5-Meter I/O Connection Length: Optimized for linking I/O modules to FTAs in control rooms and skid-mounted enclosures, minimizing cable clutter.
  2. 34-Core 24 AWG Stranded Copper Cable: Delivers isolated power and signal paths for digital/analog output modules, supporting 24V/120Vdc signals.
  3. Dual Foil + Braid Shielding: Eliminates EMI/RFI interference, ensuring error-free signal transmission in high-noise industrial environments.
  4. 96-Way Type ‘C’ Keyed Connectors: Prevents reverse polarity and misconnection; ensures secure mating with Trusted chassis I/O slots.
  5. SIL 3 Compliance: Certified to IEC 61508 SIL 3, maintaining safety loop integrity for SIS applications.
  6. Oil-Resistant PVC Jacket: Withstands industrial oils, chemicals, and mechanical stress for long-term durability.
  7. UL 94 V-0 Flame Retardancy: Self-extinguishes quickly to reduce fire risk in control rooms.
  8. Hot-Swap Compatibility: Supports module replacement without system shutdown, minimizing maintenance downtime.
  9. Molded Strain Relief: Reinforced stress points prevent cable damage from repeated bending or pulling.
  10. Field Termination Assembly (FTA) Compatibility: Directly interfaces with T8850C FTAs for isolated field signal termination.
  11. Factory-Tested Performance: 100% tested for continuity, insulation, and shielding to ensure consistent quality.
  12. Anti-Static Packaging: Factory-sealed bag with desiccant protects connectors from static damage and moisture during storage.

Application Scenarios

  1. Oil & Gas Refinery Emergency Shutdown (ESD) Systems: Connects T8400 digital output modules to FTAs for valve actuation and pump control, using dual shielding to protect safety loops from high-voltage transient interference.
  2. Chemical Plant Reactor Temperature Control: Links T8450 analog output modules to FTAs for proportional control of heating/cooling systems, maintaining SIL 3 compliance during batch processing.
  3. Power Generation Turbine Protection: Connects I/O modules to FTAs for lube oil pressure and vibration monitoring, enabling hot-swap diagnostics without turbine shutdown.
  4. Marine Offshore FPSO Fire & Gas (F&G) Systems: Interfaces T8400 modules with FTAs for alarm and suppression system actuation, with oil-resistant jacket and strain relief to withstand saltwater mist and vibration.
  5. Pharmaceutical Batch Process Control: Connects analog output modules to FTAs for FDA-compliant flow and pressure control, ensuring noise-immune signal transmission for validation-ready processes.
  6. Mining Hoist Safety Control: Links I/O modules to FTAs for hoist speed and brake system actuation, using dual shielding to eliminate interference from underground mining equipment while maintaining SIL 3 integrity.

Additional Information

  • Origin: United States
  • Warranty: 12-month warranty for new original cables; extended support via Rockwell Automation service contracts
  • Compatibility: Trusted T8400 digital output modules, T8450 analog output modules, T8850C FTAs, T8100 series chassis
  • Installation: Plug-and-play with keyed Type ‘C’ connectors; no tools required for chassis mating
  • Maintenance: Inspect connectors for dust or corrosion; clean with lint-free wipes and isopropyl alcohol; store in anti-static packaging when not in use
  • Accessories: Dust cap for Type ‘C’ connector, installation guide, and cable tie included in factory packaging
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “ICS Triplex TC-505-02-4M5 4.5-Meter Trusted I/O SmartSlot Cable”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.