ICS Triplex T9300 3‑Slot Passive I/O Backplane

Technical Specifications

  1. Mechanical Specifications
    • Material: Powder‑coated metal alloy frame with flame‑retardant polymer insulators
    • Form Factor: 3‑slot passive I/O backplane for AADvance systems
    • Dimensions: 236 mm (width) × 132 mm (depth) × 30 mm (height) (9.29 in × 5.20 in × 1.18 in)
    • Weight: 0.133 kg (0.293 lb)
    • Mounting: Top/bottom clips for secure chassis attachment; tool‑free installation
    • Protection Rating: IP20 (dust and finger contact protection)
    • Color: Black (matches AADvance controller chassis for uniform appearance)
  2. Electrical Specifications
    • Power Input: 18–32 VDC (compatible with AADvance system power supplies)
    • Maximum Total Current: 9.6 A (400 mA per I/O slot)
    • Signal Routing: Passive backplane architecture; redundant signal paths for critical I/O
    • Backplane Bus: AADvance proprietary high‑speed bus for module communication
    • Power Distribution: Dedicated power rails for each slot to prevent cross‑slot interference
Category:
Description
  1. Environmental Specifications
    • Operating Temperature: -20°C to +70°C (-4°F to 158°F)
    • Storage Temperature: -40°C to +85°C (-40°F to 185°F)
    • Relative Humidity: 10%–95% (non‑condensing)
    • Vibration Resistance: Compliant with IEC 60068‑2‑6 (2 g, 10–150 Hz)
    • Shock Resistance: Compliant with IEC 60068‑2‑27 (15 g, 11 ms duration)
    • EMI/RFI Immunity: Compliant with EN 61000‑6‑2 (industrial immunity) and EN 61000‑6‑4 (industrial emissions)
  2. Compliance & Compatibility
    • Compliance: CE marked; UL listed for industrial control equipment; IEC 61508 SIL 3 certified
    • System Compatibility: ICS Triplex AADvance controller systems; T9100 processor base units
    • Module Compatibility: All AADvance digital, analog, and specialty I/O modules
    • Expansion Compatibility: Supports T9310 expansion cables for linking multiple T9300 backplanes
    • Regulatory Approvals: RoHS compliant; compliant with ANSI/ISA 84.00.01 safety standards
  3. Installation & Maintenance
    • Installation Method: Tool‑free mounting via top/bottom clips; plug‑and‑socket module insertion
    • Expansion Setup: Connect to T9100 or other T9300 backplanes using T9310 expansion cables
    • Maintenance: No periodic calibration required; inspect for physical damage quarterly
    • Replacement Cycle: Indefinite service life under normal operating conditions; replace if bent or damaged

Functional Features

  1. 3‑Slot I/O Expansion: Supports up to three AADvance I/O modules for flexible I/O configuration.
  2. Passive Architecture: Minimizes power consumption and failure points for enhanced reliability.
  3. SIL 3 Compliance Support: Preserves system integrity to meet IEC 61508 SIL 3 safety requirements.
  4. T9310 Expansion Capability: Links to additional T9300 backplanes for scalable I/O capacity.
  5. Direct Plug‑and‑Socket Connections: Enables quick, tool‑free I/O module installation/removal.
  6. Secure Mounting Clips: Top/bottom clips ensure stable chassis attachment in high‑vibration environments.
  7. Redundant Power Distribution: Dedicated slot power rails prevent cross‑slot power interference.
  8. EMI/RFI Immunity: Shields signals from electromagnetic interference for reliable data transmission.
  9. AADvance Processor Integration: Seamlessly connects to T9100 processor base units for centralized control.
  10. IP20 Protection: Maintains chassis dust and finger contact protection for backplane components.
  11. RoHS Compliance: Meets environmental standards for hazardous substance restrictions.
  12. Uniform Chassis Aesthetics: Black color matches AADvance controller chassis for consistent appearance.

Application Scenarios

  1. Oil & Gas ESD System Expansion: Adds 3‑slot I/O capacity to AADvance ESD systems in offshore platforms, supporting phased installation of pressure, temperature, and emergency shutdown modules.
  2. Chemical Plant Safety Interlocks: Expands I/O for AADvance SIS in chemical refineries, connecting to toxic gas detectors, valve positioners, and emergency isolation systems while maintaining SIL 3 compliance.
  3. Power Generation Turbine Protection: Integrates with T9100 processors to add I/O for turbine vibration sensors, temperature transmitters, and trip relays in combined cycle power plants.
  4. Pharmaceutical Batch Processing: Extends AADvance I/O for FDA‑compliant batch systems, connecting to flow meters, level sensors, and control valves in clean‑room environments.
  5. Marine Offshore Fire & Gas Systems: Expands I/O capacity for AADvance fire & gas systems, supporting smoke detectors, flame sensors, and alarm actuators in harsh marine settings.
  6. Mining Process Automation: Adds I/O for AADvance controllers in mining operations, connecting to conveyor belt sensors, pump control modules, and emergency stop systems in high‑dust environments.

Additional Information

  • Origin: United States
  • Warranty: 12‑month warranty for new original units; extended support via Rockwell Automation service contracts
  • Compatibility: AADvance controller systems, T9100 processor base units, all AADvance I/O modules, T9310 expansion cables
  • Installation: Tool‑free mounting; plug‑and‑socket module insertion; T9310 cable‑linked expansion
  • Maintenance: Inspect quarterly for physical damage; replace if bent, cracked, or corroded
  • Accessories: T9310 expansion cables (required for backplane linking); T9191/T9193 blanking covers for unused slots
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “ICS Triplex T9300 3‑Slot Passive I/O Backplane”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.