Technical Specifications

  1. Mechanical Specifications
    • Form Factor: 19‑inch rack‑mountable (1U height); Panel‑mountable option available
    • Enclosure: Steel chassis with IP20 protection against dust and finger contact
    • Dimensions (H×W×D): 44 mm × 483 mm × 267 mm (1.73 in × 19.0 in × 10.5 in)
    • Weight: 1.2 kg (2.65 lb)
    • Front Panel: Power LED (green), status LED (green/amber/red), alarm LED (red), Ethernet activity LEDs (2 × green), reset button
    • Mounting: 1U rack‑mount (standard); 4‑point bolt‑down for panel installation
    • Connectors: 2 × RJ45 Ethernet ports (10/100 Mbps, redundant); 2 × IEC 60320 C13 power connectors (redundant); 1 × USB 2.0 port (configuration); 1 × RS232 serial port (diagnostics)
    • Electrical Specifications
      • Power Supply: 100–240 VAC (50/60 Hz); redundant input feeds for fault tolerance
      • Power Consumption: 5 W maximum (typical 3 W)
      • Operating Voltage Range: 85–264 VAC (wide‑range input)
      • Current Draw: 0.5 A (100 VAC); 0.25 A (240 VAC)
      • Isolation: 2500 VDC galvanic isolation between Ethernet ports and backplane
      • Redundancy: Dual hot‑swappable power supplies (optional); redundant Ethernet ports with automatic failover
Category:
Description
  1. Software & Protocol Specifications
    • Operating System: Dedicated embedded Linux (optimized for industrial data transfer)
    • Protocol Support: OPC DA 3.0 (Data Access); OPC AE 1.1 (Alarms & Events); OPC UA 1.04 (Unified Architecture)
    • Data Points: Up to 10,000 concurrent OPC DA tags; up to 5,000 OPC AE events per second
    • Update Rate: 100 ms minimum for OPC DA; 50 ms minimum for OPC AE
    • Security: SSL/TLS 1.2–1.3 encryption; role‑based access control (RBAC); password‑protected configuration
    • Configuration: Web‑based GUI (HTTPS); command‑line interface (CLI) via SSH; OPC UA configuration tool
    • Diagnostics: Remote monitoring via SNMP v3; email alert notifications; event logging (10,000 event buffer)
  2. Environmental Specifications
    • Operating Temperature: 0°C to +60°C (32°F to 140°F)
    • Storage Temperature: -25°C to +70°C (-13°F to 158°F)
    • Relative Humidity: 10%–95% (non‑condensing)
    • Shock Resistance: 15 g, 11 ms duration (per IEC 60068‑2‑27)
    • Vibration Resistance: 2 g, 10–150 Hz (per IEC 60068‑2‑6)
    • EMI/EMC Compliance: EN 61000‑6‑2 (immunity), EN 61000‑6‑4 (emissions); CE, UL certified
    • Safety Compliance: TÜV Certified IEC 61508 SIL 3 (for data transfer in safety applications); UL 61010‑1; CSA C22.2 No. 61010‑1

Functional Features

  1. Trusted SIS Integration: Direct backplane connection to T8100/T8300 chassis; no external communication modules required.
  2. Triple OPC Protocol Support: OPC DA 3.0 (real‑time data), OPC AE 1.1 (alarms/events), OPC UA 1.04 (unified architecture).
  3. Redundant Ethernet: 2 × 10/100 Mbps ports with automatic failover for high availability.
  4. SSL/TLS Encryption: Secures data transfer between SIS and enterprise applications.
  5. Role‑Based Access Control: Limits configuration and data access to authorized users.
  6. Web‑Based Configuration: Intuitive GUI for setup, protocol mapping, and diagnostics.
  7. Front‑Panel Status LEDs: Power, status, alarm, and Ethernet activity indicators for rapid troubleshooting.
  8. Remote Diagnostics: SNMP v3 monitoring and email alerts for proactive maintenance.
  9. High Data Capacity: Up to 10,000 concurrent OPC DA tags; 5,000 AE events per second.
  10. Embedded OS: Optimized Linux kernel for industrial data transfer; no external OS licensing required.
  11. SIL 3 Compliance: Validated for IEC 61508 SIL 3 safety applications.
  12. Historical Data Integration: OPC UA support for seamless connection to data historians.
  13. Hot‑Swappable Power Supplies: Optional redundant power for fault tolerance.
  14. USB/Serial Diagnostics: Local configuration and troubleshooting via USB or RS232.
  15. Automatic Protocol Conversion: Translates Trusted SIS data to OPC‑standard formats.

Application Scenarios

  1. Oil & Gas ESD Systems: Provides OPC access to emergency shutdown system data for HMI monitoring and SCADA integration, with redundant Ethernet ensuring data availability during critical events.
  2. Chemical Plant Safety Interlocks: Transmits safety interlock alarms and events (OPC AE) to enterprise alarm systems, enabling rapid response to process deviations.
  3. Power Generation Turbine Protection: Integrates turbine safety controller data with plant historians (OPC UA) for performance analysis and regulatory compliance.
  4. Refinery Process Automation: Connects safety instrumented systems to distributed control systems (DCS) via OPC DA, ensuring real‑time visibility of safety‑critical parameters.
  5. Marine Offshore Platforms: Delivers safety system data to vessel monitoring systems, with SSL/TLS encryption protecting data over satellite links.
  6. Pharmaceutical Manufacturing: Provides secure OPC access to batch record data for FDA compliance, with role‑based access control limiting data access to authorized personnel.

Additional Information

  • Origin: United States
  • Warranty: 12‑month warranty for new original units; extended warranties via Rockwell Automation service contracts
  • Compatibility: Trusted T8100 controller chassis, T8300 expander chassis, T8400‑series I/O modules, OPC‑compliant HMIs/SCADA/historians
  • Installation: 1U rack‑mount or panel‑mount; connect to Trusted chassis via backplane; configure via web GUI or CLI
  • Maintenance: Remote diagnostics via SNMP/email; firmware updates via USB or Ethernet; no periodic calibration required
  • Accessories: Redundant power supply kit, rack‑mount ears, Ethernet cables, USB configuration cable, OPC UA client software
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “ICS Triplex T9030 Trusted OPC Portal Server”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.