  • Input and Signal Parameters
    • It supports 24V AC/DC input voltage, with a recommended input voltage range of 20 – 42.5V DC and a maximum allowable voltage of 42.5V AC/DC.
    • It is configured with 32 input channels, which are grouped into commoned units of 8 channels each. The input frequency is 47 – 63Hz for AC 24V and 50Hz for DC 24V, with a millisecond-level response time to capture field signal changes rapidly.
    • The point isolation voltage reaches 1500V DC, which effectively isolates external electromagnetic interference and ensures the accuracy and stability of input signals.
  • Power and Physical Parameters
    • It uses a 24V DC power supply and has a power consumption of less than 5W, which matches the power configuration of most industrial control systems.
    • It is designed for 19-inch rack installation, with dimensions of 150mm in width, 80mm in height and 50mm in depth. Its actual weight is 4 kilograms, and the transport weight is 10.5 kilograms.
Category:
Description
    • Environmental Parameters
      • It has an industrial-grade operating temperature range of -40°C to 70°C, which enables it to work stably in extreme temperature environments in industrial sites.
      • It has a protection level of IP66, and can operate normally in environments with high humidity and dust, without being affected by harsh environmental conditions.
  • Functional Features
    • Redundant Design Ensures Operational Stability
      • The module adopts a redundant design that eliminates the impact of single-point faults. Even if a partial circuit malfunctions during operation, the redundant mechanism can quickly take over the work. This design maintains the continuous collection and transmission of signals, which is essential for the stable operation of safety-critical systems.
      • The 1500V DC isolation between channels prevents signal interference between different input channels, ensuring that each channel can independently and accurately collect and transmit signals.
    • Comprehensive Self-Diagnosis and Fault Recognition
      • The module performs continuous self-diagnosis on each input channel and its internal circuits during operation. Once a fault such as a signal stuck-on state or circuit abnormality is detected, it can immediately send out fault signals.
      • It is equipped with status indicators for each channel, which display pass, fault and active states respectively. These indicators allow maintenance personnel to quickly locate fault points and improve maintenance efficiency.
    • Open Software and Multi-Protocol Compatibility
      • It complies with the IEC 61131 – 3 standard configuration language, including functional block diagram, ladder diagram and structured text, etc. It supports offline and online programming as well as online editing, deletion and addition of databases.
      • It supports integrated development environments and global unified engineering real-time databases, which can store 100,000 points of real-time data and 100,000 points of historical data. It also supports multiple communication protocols such as Modbus and Profibus to achieve seamless data exchange with upper-level systems.
  • Application Scenarios
    • Oil and Gas Industry
      • In offshore drilling platforms and onshore refineries, it is integrated into emergency shutdown systems and fire and gas detection systems. It collects signals from emergency stop buttons, valve position sensors and gas detection switches, and transmits these signals to the controller to trigger emergency shutdowns or fire suppression measures when oil and gas leaks or fires occur.
      • In oil and gas transmission pipelines, it monitors signals from pressure switches and leakage sensors. When abnormal pressure or leakage is detected, it collaborates with the controller to control the opening and closing of isolation valves, preventing pipeline bursts and reducing leakage losses.
    • Chemical and Pharmaceutical Industry
      • In chemical production workshops handling flammable and explosive raw materials, it is used in reactor safety interlock systems. It collects signals from temperature and pressure switches on reactors. When process parameters exceed safe limits, it sends signals to cut off the feeding system immediately to avoid dangerous reactions.
      • In pharmaceutical production lines with strict process requirements, it connects with various process control switches and position sensors. It monitors the on-off state of key equipment in real time to ensure that each production link complies with safety and quality standards, which meets the strict compliance requirements of pharmaceutical production.
    • Power and Metallurgical Industry
      • In thermal power plants and nuclear power plants, it is applied to the safety protection systems of boilers, steam turbines and other key equipment. It collects status signals from safety valves and pressure relief devices, and transmits fault signals to the controller to shut down relevant equipment in time when abnormalities occur.
      • In iron and steel metallurgical plants, it is integrated into blast furnace and converter control systems. It collects signals from material level switches and temperature switches in the furnace, providing data support for adjusting feeding speed and air supply volume, which maintains the stability of the smelting process and improves product quality.
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Triconex 3503EN High-Reliability Digital Input Module”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.