ABB CI534V02 3BSE010700R1 Profibus DP-V1 Communication Interface Module (for AC 800M DCS)

Technical Specifications

  • Communication Performance:
    • Protocol Support: Profibus DP-V1 (compliant with IEC 61158-3-1); backward compatible with Profibus DP-V0
    • Communication Rate: 9.6 kbps – 12 Mbps (auto-negotiation or manual configuration)
    • Maximum Nodes: Up to 124 Profibus DP slave devices per module
    • Cyclic Data Transfer: Supports real-time process data exchange (typical update time <1ms at 12 Mbps)
    • Acyclic Data Transfer: Supports FDL (Fieldbus Data Link) and DPV1 acyclic services (for device parameterization and diagnostics)
    • Bus Topology: Line topology (supports redundant bus configuration for high availability)
  • Electrical Parameters:
    • Power Supply: 24V DC (from AC 800M controller backplane); Power consumption: 3W (max)
    • Profibus DP Interface: 2 x Sub-D9 male connectors (for primary and redundant bus, if used)
    • Isolation: 500V AC galvanic isolation between Profibus bus and controller backplane
Category:
Description
  • Environmental Ratings:
    • Operating Temperature: -25°C – +70°C
    • Storage Temperature: -40°C – +85°C
    • Relative Humidity: 5% – 95% (non-condensing, no dew formation)
    • Protection Class: IP20 (module housing, when installed in a control cabinet)
    • Vibration Resistance: IEC 60068-2-6, 10–500 Hz, 0.15mm amplitude (operating); 0.3mm amplitude (non-operating)
    • Shock Resistance: IEC 60068-2-27, 15g acceleration, 11ms duration (half-sine wave, non-operating)
  • Mechanical & Installation:
    • Dimensions (W x H x D): 120mm x 140mm x 25mm (compatible with AC 800M controller racks)
    • Mounting: Plug-in installation on AC 800M controller backplane (no external tools required for insertion/removal)
    • Weight: 150g

Functional Features

  • Dual Bus Redundancy: Supports redundant Profibus DP bus configuration (primary/secondary bus), ensuring uninterrupted communication if one bus fails—critical for safety-critical or high-availability applications.
  • Dual Communication Modes: Combines Profibus DP-V1’s cyclic (real-time) and acyclic (non-real-time) communication, enabling both fast process control and flexible device management (e.g., online parameter adjustment, fault diagnosis).
  • Built-in Diagnostics: Provides comprehensive diagnostic data (bus status, slave device connectivity, error codes) via AC 800M’s Control Builder M software, allowing quick identification of communication faults (e.g., loose connections, bus short circuits).
  • High Compatibility: Seamlessly integrates with ABB’s AC 800M DCS and S800 I/O modules; compatible with third-party Profibus DP-V0/V1 slave devices (e.g., drives, sensors, valves) from other manufacturers.
  • Galvanic Isolation: 500V AC isolation between the Profibus bus and controller backplane prevents electrical interference or ground loops from damaging the module or controller.
  • Auto-Baud Rate Detection: Automatically detects and adapts to the Profibus bus communication rate (9.6 kbps – 12 Mbps), simplifying commissioning and reducing configuration errors.

Application Scenarios

  • Process Industries:
    • Oil & Gas: Integrates with Profibus DP-enabled flow meters, pressure transmitters, and control valves in upstream wellhead control or downstream refining processes—ensuring real-time data for process optimization.
    • Chemical & Petrochemical: Connects to distributed I/O modules (e.g., ABB S800 I/O) and motor drives in batch reactors or continuous mixing systems, enabling synchronized control of multiple devices.
  • Power Generation:
    • Thermal Power Plants: Links AC 800M controllers to Profibus DP-based turbine sensors, boiler level transmitters, and feedwater pumps—supporting real-time monitoring of critical power generation processes.
    • Renewable Energy: Connects to wind turbine converters or solar inverter Profibus DP interfaces, facilitating data collection for grid integration and performance monitoring.
  • Manufacturing Industries:
    • Automotive: Integrates with Profibus DP-enabled robotic arms, conveyor drives, and quality inspection sensors in assembly lines—enabling synchronized motion control and production data tracking.
    • Pulp & Paper: Connects to paper machine speed drives, web tension sensors, and dryer temperature controllers, ensuring consistent product quality via real-time process adjustments.
  • Water & Wastewater Treatment:
    • Links AC 800M controllers to Profibus DP-based pump drives, flow sensors, and pH analyzers in filtration or disinfection systems—optimizing water treatment efficiency and ensuring compliance with discharge standards.
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “ABB CI534V02 3BSE010700R1 Profibus DP-V1 Communication Interface Module (for AC 800M DCS)”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.