ABB SA9923A-E HIEE450964R0001

Technical Specifications

  • Signal Input Types:
    • Analog inputs: AC voltage (0-690 V rms), AC current (0-5 A rms, via CTs), DC voltage (0-1000 V), DC current (0-10 A)
    • Digital inputs: 8 discrete digital channels (24 V DC, dry/wet contact compatible)
    • Pulse inputs: 4 high-speed pulse channels (0-24 V DC, for encoder or counter signals)
  • Signal Processing Performance:
    • Sampling rate: Up to 500 kHz per analog channel (captures high-frequency transients)
    • Resolution: 24-bit ADC (Analog-to-Digital Converter) for analog signals; 16-bit for digital pulse counting
    • Frequency response: DC to 20 kHz (covers industrial/power system signal bandwidths)
  • Measurement Accuracy:
    • AC voltage/current (50/60 Hz): ±0.05% of full scale (FS) at 25°C
    • DC voltage/current: ±0.02% of full scale (FS) at 25°C
    • Pulse counting: ±1 count error (up to 1 MHz input frequency)
Category:
Description
  • Isolation:
    • Channel-to-channel isolation: 2500 V AC (rms) for 1 minute (critical for high-voltage applications)
    • Module-to-backplane isolation: 3000 V AC (rms) for 1 minute (protects control systems from transients)
  • Data Storage & Output:
    • Onboard memory: 64 MB RAM (real-time data buffer); 128 MB Flash (configuration/fault logs)
    • Output data: Processed parameters (RMS, peak, frequency, THD), raw sampled data, and digital status
  • Operating Temperature Range: -40°C to +70°C (extreme environment compatibility)
    • Storage Temperature Range: -55°C to +85°C
  • Power Supply Requirements:
    • Input voltage: 24 V DC (redundant input supported; 19.2 V DC to 30 V DC tolerance)
    • Maximum power consumption: 10 W (under full-load sampling)
  • Communication Interfaces:
    • Primary: Ethernet (10/100/1000 Mbps, RJ45; supports TCP/IP, IEC 61850 MMS)
    • Secondary: RS-485 (supports Modbus RTU for legacy system integration)
  • Mechanical Dimensions:
    • Width: Approximately 48 mm (35 mm DIN rail-mountable)
    • Height: Approximately 175 mm
    • Depth: Approximately 220 mm
  • Certifications:
    • IEC 61850-3 (power system automation standard)
    • IEC 61000-6-2 (EMC immunity for industrial/power environments)
    • IEC 61000-6-4 (EMC emissions)
    • UL 508 (North American industrial control safety)
    • CE marking (EU industrial compliance)

Function Features

  • Multi-Signal Acquisition: Supports analog (AC/DC voltage/current), digital, and high-speed pulse signals—eliminating the need for multiple single-function modules and simplifying system architecture.
  • Ultra-High Precision: 24-bit ADC and ±0.05% FS accuracy ensure precise measurement of critical parameters (e.g., power grid voltage, motor current), enabling accurate process control and performance analysis.
  • High-Frequency Transient Capture: 500 kHz sampling rate captures fast electrical transients (e.g., voltage spikes, current surges in power systems), supporting post-fault analysis and predictive maintenance.
  • High-Voltage Isolation: 2500 V AC channel isolation and 3000 V AC module isolation protect operators and control systems from high-voltage hazards in power grids or industrial high-power equipment.
  • Advanced Signal Analysis: Built-in DSP algorithms calculate real-time parameters including RMS value, peak value, frequency, total harmonic distortion (THD), and phase angle—providing deep insights into equipment health.
  • Redundant Power Support: Dual 24 V DC power inputs ensure uninterrupted operation if one power source fails, critical for mission-critical applications like power substation monitoring.
  • IEC 61850 Compatibility: Native support for IEC 61850 (global power system automation standard) enables seamless integration with smart grids, substations, and power plant control systems.
  • Comprehensive Diagnostics: Monitors module health (temperature, power supply), input signal integrity (overload, open circuit), and communication status. Fault data is logged with time stamps (≤1 μs accuracy) and transmitted to the central system for rapid troubleshooting.
  • Rugged Design: Withstands -40°C to +70°C temperatures, vibration (up to 10 g peak), and shock (up to 30 g peak)—reliable in outdoor substations, mines, or heavy industry.

Application Scenarios

  • Power System Automation:
    • Smart Substations: Monitors transformer voltage/current, detects grid transients (e.g., lightning surges), and calculates power quality metrics (THD, frequency deviation). IEC 61850 compatibility integrates with substation SCADA for grid stability.
    • Power Plants (Thermal/Hydro/Nuclear): Analyzes generator output parameters, turbine auxiliary system current, and boiler feedwater flow. High-precision data supports optimal power generation and equipment wear prediction.
    • Renewable Energy (Solar/Wind): Tracks inverter output voltage/current, grid connection frequency, and battery storage current. Captures voltage fluctuations from intermittent renewables to aid grid synchronization.
  • Heavy Industry:
    • Steel & Metallurgy: Monitors rolling mill motor current, furnace temperature (via DC voltage signals from thermocouples), and conveyor belt encoder pulses. Detects current imbalances to prevent motor failure.
    • Mining: Tracks crusher motor current, conveyor belt speed (via pulse encoders), and hydraulic system pressure. Rugged design withstands dust, vibration, and extreme temperatures in underground/open-pit mines.
    • Petrochemical: Monitors pump motor current, pipeline pressure (via analog signals), and valve status (digital inputs). High-speed sampling captures pressure surges to prevent pipeline damage.
  • Critical Infrastructure:
    • Data Centers: Monitors UPS output voltage/current, server rack power consumption, and cooling system pump status. Ensures stable power delivery to avoid data loss.
    • Railway Electrification: Analyzes traction substation voltage, train pantograph current, and track circuit signals. Detects power quality issues to maintain reliable train operation.
    • Water & Wastewater Treatment: Captures pump current, chemical dosage flow (via analog signals), and tank level switch status. Precise data optimizes treatment processes and reduces energy use.
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “ABB SA9923A-E HIEE450964R0001”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.