TRICONEX 3000470-510
Technical Specifications
- Brand: Invensys Triconex
- Origin: France
- Model Number: 3000470-510
- Work Voltage: 240V
- Output Frequency: Up to 100kHz
- Operating Temperature Range: -25°C to 85°C (operation); -60°C to 125°C (storage)
- Humidity Range: 5% to 95% RH (non-condensing)
- Dimensions: Approximately 234mm in length
- Weight: Between 2kg and 7kg
- Certifications: Compliant with IEC 61508 SIL 3 and other international safety standards
TRICONEX 3000110-360
Technical Specifications
- Brand: Invensys (now part of Schneider Electric)
- Origin: United States
- Physical Dimensions: Approximately 200mm × 150mm × 80mm
- Weight: Around 0.5 kg
- Power Supply: Supports redundant power inputs for enhanced reliability.
- Operating Temperature: -20°C to +70°C (industrial-grade reliability).
- Storage Temperature: -50°C to +85°C.
- Mounting: Rack-mounted design for easy integration into Triconex systems.
- Certifications: Complies with IEC 61508 SIL 3 and other international safety standards.
TRICONEX 2481 Backplane Module
Technical Specifications
- Model: TRICONEX 2481
- Brand: Invensys (now part of Schneider Electric)
- Origin: Switzerland
- Dimensions: Approximately 200mm × 150mm × 80mm
- Weight: Around 0.5 kg
- Power Supply: Supports redundant power inputs for enhanced reliability.
- Operating Temperature: -20°C to +70°C (industrial-grade reliability).
- Storage Temperature: -50°C to +85°C.
- Mounting: Rack-mounted design for easy integration into Triconex systems.
- Certifications: Complies with IEC 61508 SIL 3 and other international safety standards.
TRICONEX 2351 Analog Input Backplane Module
Technical Specifications
- Input Types: Supports multiple analog input signals, including current (4-20mA, 0-20mA), voltage (±10V to ±100V), thermocouples, and RTDs (e.g., Pt100).
- Resolution: 16-bit high-resolution measurement for accurate signal conversion.
- Accuracy: ±0.1% FSR (Full-Scale Range) to minimize measurement errors.
- Update Rate: Real-time data refresh for dynamic process monitoring.
- Power Supply: 24V DC input with stable voltage regulation.
- Operating Temperature: -20°C to +70°C (industrial-grade reliability).
- Storage Temperature: -50°C to +85°C for harsh environmental conditions.
- Dimensions: 200mm x 150mm x 80mm (compact design for space-efficient installations).
- Weight: Approximately 0.5 kg.
- Safety Certifications: Complies with IEC 61508 SIL3 and ISA-S84 standards for safety-critical applications.
TRICONEX MA2211-100 Digital Input Module
Technical Specifications
- Input Channels: Multiple digital input channels for connecting external digital signals.
- Electrical Isolation: Provides electrical isolation to prevent external interference and enhance system reliability.
- Communication Interface: Features communication interfaces (e.g., PCIe-based design) for seamless integration with PLCs, DCS, or other control systems.
- Redundancy: Supports TMR architecture, enabling continuous operation even if one channel fails.
- Measurement Capabilities: Can measure physical parameters like temperature, pressure, flow, humidity, and liquid levels with high precision.
- Compliance: Meets industrial standards such as IEC 61508 (SIL 3) for safety-critical applications.
TRICONEX 2000361-001 Digital Output Module part of Triconex Tricon system
Technical Specifications
- Brand: TRICONEX (a Schneider Electric brand)
- Model: 2000361-001
- Redundancy: Triple-modular redundant (TMR) design with three independent channels per output signal.
- Output Type: Digital outputs (specific voltage/current ratings depend on system configuration).
- Diagnostic Coverage: Full hardware and software diagnostics for each channel, including output feedback verification.
- Communication: Integrated into the Triconex Tricon system via TriBus for real-time data exchange between modules.
- Environmental: Designed for harsh industrial environments with high resistance to electromagnetic interference (EMI) and temperature extremes.
- Certifications: Complies with international safety standards such as IEC 61508 (SIL 3), TÜV, and other industry-specific approvals.
Triconex 9853-610 Analog Input Terminal Block
Technical Specifications
- Electrical Parameters
- It supports multiple analog input ranges, including 0 - 10V, -10V to 10V, 4 - 20mA, and 0 - 20mA, covering the signal requirements of most industrial field sensors.
- It has a measurement accuracy of ±0.1% and a resolution of 12 bits, and the signal update rate reaches 250ms, which can ensure the accuracy and real-time performance of data collection.
- It uses a 24VDC power supply, with a power consumption of only 5W, which will not add excessive power burden to the overall safety system.
- Physical Parameters
- Its overall dimensions are 110mm × 45mm × 22mm, and its weight is 150g. The compact and lightweight design allows it to be flexibly installed in control cabinets with limited space.
- It is equipped with screw-type terminals, which can provide firm wiring connections and avoid poor contact caused by vibration in industrial environments.
Triconex 9750-210 32-Point Current Input Terminal Board
Technical Specifications
- Electrical Parameters
- It supports active analog current output with ranges of 4 to 20 mA and 0 to 1 mA, and the accuracy of the 4 to 20 mA range reaches ±1% of full scale.
- The maximum load for the 4 to 20 mA range is 1200 ohms, while the maximum load for the 0 to 1 mA range is 10 k ohms. It achieves 36 Vpk isolation from RTDs and analog inputs to avoid signal interference.
- It is equipped with 4 assignable outputs that can be configured for parameters such as phase currents, phase voltages, three - phase average power, and motor load torque as required.
- Physical Parameters
- Its overall dimensions are 45 cm × 20 cm × 15 cm, and it weighs 3 kg, which is suitable for installation in standard industrial control cabinets.
- It adopts a modular structural design that conforms to the installation standards of Triconex series modules, facilitating quick assembly with the system chassis and later disassembly for maintenance.
Triconex 9662-610 Standard Termination Panel
Technical Specifications
- Electrical Parameters
- It adopts 24 VDC termination option and has an input voltage range of 0 to 55 VDC, which can adapt to the voltage requirements of different field digital output devices.
- The long - term drift is less than 0.3%, and the frequency range covers 14 to 60 kHz, ensuring the stability of signal transmission.
- The maximum power consumption of the panel is 10 W, which will not cause excessive power load to the overall safety system during long - term operation.
- Physical Parameters
- Its overall dimensions are 12.7 cm × 12.7 cm × 5.1 cm, and the weight is 0.3 kg. The compact size allows it to be installed in control cabinets with limited space.
- It adopts DIN rail installation mode, and the installation process is simple and efficient, which is convenient for quick assembly and later position adjustment.
Triconex 9573-110F Analog Input Communication Module
Technical Specifications
- Signal Processing Parameters
- It can convert small signals based on high common - mode voltage into single - ended signals relative to the system chassis ground, which effectively solves the interference problem of high common - mode voltage on signal transmission.
- The built - in isolation amplifier can amplify weak analog input signals. The signal filtering function can filter out external noise, and the measurement resolution and accuracy of analog signals are significantly improved after processing.
- It supports 8 PI points and 16 PTI points, which can meet the collection and processing needs of multiple groups of analog signals at the same time.
- Physical Parameters
- It adopts a standard industrial control card design, which is consistent with the installation size of Triconex series module slots. It can be directly inserted into the dedicated position of the Triconex system chassis for installation.
- The module uses a hard metal shell, which has good physical protection performance. The wiring interface adopts a standard terminal design, which facilitates firm connection with field sensors and internal system lines.
Triconex 9563-810 Digital Input Termination Panel
Technical Specifications
- Electrical Parameters
- It is equipped with 32 digital input channels, and each channel has independent electrical isolation performance, with an isolation voltage of 1500V AC between the channels and the ground.
- The standard input voltage is 24 VDC, the typical input current is 2.5 mA, and the maximum input current is 3.3 mA. The power consumption of the whole module is less than 5 W.
- The response time of the input signal is less than 2 ms, which can quickly capture the changes of on - site equipment signals and ensure the real - time performance of system control.
- Physical Parameters
- Its overall dimensions are 171mm × 89mm × 46mm, and the weight is about 0.9 kg to 1 kg, which is compact and easy to install in limited control cabinet space.
- It supports DIN rail installation and rack - mounted installation. The screw terminal design is adopted for wiring, which is firm and not easy to loose, reducing the risk of poor contact.
Triconex 8521 Ethernet Communication Module
Technical Specifications
- Communication Parameters
- It supports 10Mbps and 100Mbps Ethernet communication rates. A dedicated 100M indicator light illuminates when a 100M connection is established and turns off when switching to a 10M connection.
- It is equipped with LINK/ACT indicator lights. The lights illuminate and flash when the network connection is established and data transmission is in progress, enabling intuitive monitoring of communication status.
- It supports standard Ethernet communication protocols, which facilitates seamless docking with mainstream industrial control network architectures.
- Physical Parameters
- It adopts a standard modular design that matches the installation dimensions of Triconex series chassis. The compact structure allows it to be inserted into the dedicated slot of the Triconex chassis without occupying additional space.
- It is equipped with a grounding connection terminal, and a wire needs to be connected to this terminal to realize the grounding function of the module and enhance operational stability.


Reviews