ProSoft PLX31-EIP-SIE EtherNet/IP to Siemens Industrial Ethernet Gateway

Core Function

  • Protocol Conversion: Bridges EtherNet/IP (CIP, PCCC) and Siemens Industrial Ethernet protocols for seamless interoperability between Rockwell controllers and Siemens PACs .
  • Data Exchange: Supports high-speed bidirectional transfers of up to 10,000 16-bit registers, ideal for large-scale industrial data synchronization .
Category:
Description

Technical Specifications

Communication Capabilities

Parameter Specification
EtherNet/IP Support Class 3 Server Connections: 5
Class 1 I/O Connections: 2
Max RPI: 5 ms/connection
Siemens PLC Compatibility S7-200, S7-300, S7-400, S7-1200, S7-1500 PACs
Supported Registers: DB, Inputs, Outputs, Flags, Counters, Timers
Client/Server Capacity Up to 20 Siemens clients
Modbus TCP/IP: 10 clients, 5 MBAP/5 encapsulated servers
Data Throughput 10/100 Mbps Ethernet via dual RJ45 ports (redundant-capable)

Physical & Environmental

Parameter Specification
Power Supply 24 V DC (±20%; range 10–36 V DC)
Current Consumption: 300 mA (nominal), 610 mA (max)
Dimensions 136.7 × 50.5 × 111.3 mm (5.38 × 1.99 × 4.38 in)
Operating Temperature -25°C to +70°C (-13°F to 158°F)
Protection & Durability Vibration: 5G (IEC 60068-2-6)
Shock: 15G (operational), 30G (non-operational)
EMI Isolation: 1500 Vrms
Humidity Tolerance 5–95% non-condensing

Functional Features

  1. Data Prioritization & Optimization
    • Configurable RPI (Requested Packet Interval) to prioritize critical control data .
    • Command Flexibility: Supports 100 fully configurable client commands per connection, with write-on-change efficiency .
  2. Configuration & Diagnostics
    • SD Card Slot: Stores configuration files for disaster recovery and rapid redeployment .
    • ProSoft Discovery Service: Enables IP address configuration without subnet alignment .
    • LED Status Indicators: Real-time monitoring for power (PWR), errors (ERR), network activity (NS), and module health (MS) .
  3. Reliability & Security
    • Redundancy Support: Dual Ethernet ports for failover operation .
    • Tamper Protection: Module switch (v1.04+) locks configuration against unauthorized changes .
    • Broadcast Storm Resilience: Handles ≤5,000 ARP frames/second for network stability .
  4. Industrial Robustness
    • Conformal coating option for harsh environments (e.g., chemical exposure) .
    • DIN rail mounting for tool-free installation in control cabinets .

Application Scenarios

1. Hybrid Automation Integration

  • Automotive Manufacturing: Synchronizes Rockwell ControlLogix PLCs with Siemens S7-1500 PACs on robotic assembly lines, enabling real-time coordination of conveyors and actuators .
  • Pharmaceutical Batch Processing: Bridges Emerson DeltaV (EtherNet/IP) and Siemens S7-400 PACs for recipe management and compliance data logging .

2. Real-Time Data Synchronization

  • Energy Grid Monitoring: Connects SEL RTAC (EtherNet/IP) with Siemens S7-1200 PACs to aggregate substation data for SCADA systems, with 5 ms RPI for fault detection .
  • Water Treatment Plants: Integrates ABB AC800M controllers (Modbus TCP/IP) and Siemens S7-300 PACs for pump control and turbidity monitoring .

3. Legacy System Modernization

  • Retrofitting S7-200/300 Systems: Allows older Siemens PACs to communicate with modern Rockwell PlantPAx DCS without hardware replacement .
  • Redundant Architectures: Paired with ProSoft PLX81-EIP-61850 gateways for SIL 3-compliant failover in critical safety systems (e.g., fire/gas shutdown units) .

4. Data-Intensive Applications

  • Predictive Maintenance: Exchanges vibration and temperature data between Siemens PACs and Rockwell MES systems for AI-driven analytics .
  • Packaging Machinery: Coordinates servo drives (Siemens) and HMIs (Rockwell) via 248-word I/O connections for high-speed labeling and filling .

Lifecycle & Support

  • Warranty: 12 months for new units, extendable to 18 months for refurbished products .
  • Obsolescence Management: AoteWell Automation provides lifecycle support, including phased replacements for discontinued models .
  • Firmware Updates: ProSoft Configuration Builder software enables seamless firmware upgrades and I/O mapping .

Key Industries Served

  • AutomotivePharmaceuticalsEnergy
  • Food & BeverageWater/WastewaterOil & Gas

Resolved Data Conflicts

  • Register Capacity: Earlier sources (2018) cite 4,000 registers , but 2024–2025 documentation standardizes 10,000 registers  due to hardware revisions.
  • Temperature Range: Operating range confirmed as -25°C to +70°C per ProSoft technical datasheets , overriding broader uncorroborated claims.
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “ProSoft PLX31-EIP-SIE EtherNet/IP to Siemens Industrial Ethernet Gateway”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.