GE Multilin 369-H1-R-M-F-E-H-E – Motor Management Relay

The GE 369-HI-R-M-F-E-H-E (also referred to as the Multilin 369 Motor Management Relay) is a high-performance industrial device designed for advanced motor protection, monitoring, and control in mission-critical applications. As part of GE’s Multilin product line, it combines robust hardware with programmable logic to ensure reliability in harsh environments.

Category:
Description

Technical Specifications

  • Power Supply:
    • Control Power: 50–300 VDC or 60–265 VAC (auto-ranging) with transient suppression for voltage spikes .
    • Power Consumption: ≤65 VA (max) at full load .
  • Input/Output Interfaces:
    • Current Inputs: 1 A or 5 A secondary (CT inputs) for phase and ground fault monitoring .
    • RTD Inputs: Optional 12-channel 3-wire RTD inputs (100 Ω platinum, 100 Ω nickel, 120 Ω nickel, 10 Ω copper) for temperature measurement .
    • Digital Inputs: 6 optically isolated dry contact inputs (24 VDC compatible) .
    • Digital Outputs: 4 Form C relay outputs (5 A, 250 VAC/30 VDC) for tripping, alarms, or control signals .
  • Communication:
    • Protocols: MODBUS RTU (RS-485), PROFIBUS-DP, and RS-232 for integration with SCADA/HMI systems .
    • Optional Fiber Optic Port: Baud rate 1200–19200 bps (Modbus RTU) for long-distance, noise-immune communication .
  • Physical Attributes:
    • Dimensions: 29.6 cm (H) × 10.7 cm (W) × 20.5 cm (D) (11.65″ × 4.21″ × 8.07″) .
    • Weight: ~4.5 kg (~10 lb) .
    • Mounting: DIN rail or panel-mountable with secure locking clips .
  • Environmental Ratings:
    • Temperature: -40°C to +70°C (-40°F to +158°F) with IP65 ingress protection (optional harsh environment variant) .
    • Humidity: 5–95% non-condensing (IEC 60068-2-30) .
    • Shock/Vibration: Compliant with IEC 60068-2-6 (5–500 Hz, 0.5 g) and IEC 60068-2-27 (100 m/s²) .
    • Certifications: CE, UL 61010-1, and ISA-S71.04 Class G3 (corrosive environments) .

Functional Features

  1. Comprehensive Motor Protection:
    • Overcurrent/Overload: Configurable inverse-time curves (IEC thermal model) with 堵转 (locked rotor) detection .
    • Voltage Protection: Undervoltage, overvoltage, phase unbalance, and phase reversal protection .
    • Ground Fault Detection: Sensitive residual current monitoring (0.1–100% of rated current) .
    • Temperature Monitoring: RTD inputs for stator/winding temperature surveillance with alarm/trip thresholds .
  2. Advanced Diagnostics:
    • Real-Time Health Monitoring: Continuous self-testing of CPU, memory, and communication links with LED status indicators .
    • Event Logging: Stores 512 events (timestamped with 1 ms resolution) for root-cause analysis .
    • Oscillography: Captures waveform snapshots during faults (voltage/current) for detailed troubleshooting .
  3. Programmable Control Logic:
    • IEC 61131-3 Compliance: Supports ladder logic, function block diagram, and structured text for custom control strategies .
    • Sequence of Events (SOE): Prioritized alarm annunciations with configurable setpoints for process variables .
  4. Flexible Configuration:
    • Metering Package (Optional): Measures voltage, frequency, power (kW/kVA), and energy consumption (MWh) .
    • Redundancy: Dual power supply inputs (24 VDC) for uninterrupted operation .
    • Hot-Swap Capability: Replaceable I/O modules without powering down the system .
  5. User Interface:
    • Enhanced Display: 40-character LCD with backlight for parameter adjustment and trend visualization .
    • EnerVista Software: PC-based tool for remote configuration, firmware updates, and data logging .

Application Scenarios

The 369-HI-R-M-F-E-H-E is deployed in high-reliability industrial environments across sectors:

 

  1. Oil & Gas:
    • Pumping Stations: Protects centrifugal pumps and compressors from cavitation and overheating during pipeline operations .
    • Refineries: Monitors motor-driven agitators in chemical reactors to prevent process upsets .
  2. Power Generation:
    • Steam Turbines: Controls auxiliary motors (e.g., lubrication pumps) in thermal power plants .
    • Wind Farms: Ensures grid-connected generators comply with voltage/frequency stability standards .
  3. Water/Wastewater:
    • Pump Stations: Manages submersible pumps in sewage treatment plants, detecting dry-running conditions .
    • Desalination Plants: Protects high-voltage motors driving reverse osmosis (RO) membranes .
  4. Industrial Manufacturing:
    • Mining: Safeguards conveyor belt motors and crushers from overload in mineral processing .
    • Pulp & Paper: Monitors variable-speed drives (VSDs) for paper machines, optimizing energy usage .

Typical System Integration

A standard configuration includes:

 

  • Field Devices:
    • Current Transformers (CTs): 1 A or 5 A secondary for motor phase current monitoring .
    • Resistance Temperature Detectors (RTDs): Installed in motor windings for temperature feedback .
  • Communication Network:
    • Fiber Optic Link: Connects to GE’s Mark VIe control system for real-time data exchange .
    • OPC UA Gateway: Enables integration with third-party SCADA platforms (e.g., Siemens WinCC) .
  • Human-Machine Interface (HMI):
    • GE Cimplicity HMI: Displays motor status, trends, and alarm history via a graphical dashboard .
    • Mobile Access: Remote monitoring through a web-based interface (HTTPS/TLS encrypted) .

Safety & Compliance

  • Cybersecurity: Role-based access control (RBAC) and encrypted OPC UA communication prevent unauthorized configuration changes .
  • Fail-Safe Design:
    • Hardwired Trip Circuits: Directly triggers emergency shutdowns (ESD) via discrete outputs .
    • Diagnostic Coverage: >99% self-test coverage for critical components (e.g., CPU, memory) .
  • Environmental Sustainability: RoHS-compliant lead-free design reduces ecological impact .
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “GE Multilin 369-H1-R-M-F-E-H-E – Motor Management Relay”

Your email address will not be published. Required fields are marked *

Shipping and Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.